The thermal transmittance, or U-value for short, states how much heat passes through one square metre of a building element at a temperature difference of one kelvin. The unit is W/(m²·K). The lower the number, the better the window insulates. For windows there are three values, and quotes routinely mix them up. The difference can amount to 30 % in heat loss.
For Prague apartments and houses the U-value has one more practical dimension: it decides whether you get condensation. A window with a high Uw has a cold internal surface on the glass and frame in winter, and moisture condenses on it. The result is misted glass, wet sills and, in the worst case, mould in the reveals. A good window therefore not only saves energy but protects the building.
Ug: the glazing
Ug describes the glass alone. Double glazing with a low-emissivity coating and argon fill reaches Ug 1.0 to 1.1 W/(m²·K), triple glazing 0.5 to 0.7. It is the lowest of the three values, which is why sellers like to quote it as the headline figure. But the glass is only part of the window and says nothing about the frame or the edge of the glazing unit.
Uf: the frame
Uf describes the frame and sash. A PVC profile with a 76 mm installation depth has a Uf of around 1.0 to 1.2, an 85 mm profile 0.9 to 1.0. Thermally broken aluminium 1.2 to 1.6, timber-aluminium 1.0 to 1.3. The frame is always weaker than triple glazing, hence the rule: the larger the window, the smaller the share of frame and the better the overall value.
Uw: the whole window
Uw is the value for the whole window including frame, glass and spacer. It is Uw that decides heat loss, grant eligibility and compliance with the standard. It is calculated for a reference size of 1 230 × 1 480 mm. A triple-glazed PVC window reaches Uw 0.78 to 0.95, aluminium 0.85 to 1.10. The spacer between the panes also enters the calculation: an aluminium spacer worsens Uw by 0.05 to 0.10 compared with a warm-edge plastic or stainless steel spacer. Always ask for a warm-edge spacer.
What ČSN 73 0540 says
- Required value for windows in heated buildings: Uw 1.5 W/(m²·K).
- Recommended value: Uw 1.2 W/(m²·K).
- Recommended value for passive houses: Uw 0.6 to 0.8 W/(m²·K).
- Condition for an NZÚ grant for window replacement: Uw no more than 0.90 W/(m²·K).
What to watch for in quotes
Check whether the quote states Uw or only Ug. A value of 0.5 in a quote is almost always the glass, not the window. Ask which size the Uw is stated for: a small 600 × 600 mm window will have a noticeably worse Uw than the reference size. And check the manufacturer's declaration of performance, where the values are binding. In our quotes we state the Uw for each position separately, based on its actual size.
What it means in money
A family house with 30 m² of windows and a Uw of 0.8 instead of 1.2 saves roughly 1 200 to 1 500 kWh of heat a year, which with gas heating is around 3 000 to 4 500 CZK annually. Add better acoustics and a lower risk of condensation on the glass. Triple glazing therefore pays off not only because of the grant, but even without it.